Well Test Cost-Conscious Package – Availability Update

One Available Partial Ex-Stock One Available Partial Ex-Stock MTC Asia Pacific – Singapore (including full set of spare parts & acce...

One Available Partial Ex-Stock
One Available Partial Ex-Stock MTC Asia Pacific – Singapore (including full set of spare parts & accessories)

Subject to prior sale.



    1 x 3” 5Kpsi Hydraulic Surface Safety Valve in frame with lifting sling set.

    1 x 3” 5Kpsi Choke manifold on base skid with data header, test caps, set choke beans and wrench and including lifting sling set.

    1 x 3Kpsi Emergency Shutdown Panel, twin outlet with hydraulic hoses, remote pull buttons, pressure pilots, pilot hoses and fittings.

    1 x 15Kpsi Pressure test pump with chart recorder, set hoses and fittings.

    1 x 10Kpsi Chemical injection pump with tank in SS frame.

    1 x Set of 10Kpsi Dead Weight Tester with set of weights, 10Kpsi Surface Pressure Recorder (12” chart) and Ranarex gasgravitometer for SG range of 0.5 to 2.0.

    1 x 1440psi / 42” x 10ft horizontal Separator in frame including lifting sling se. Inlet, outlet and bypass manifold with ball valves to oil and gas outlets, 6” and 2” Daniel orifice gas metering with Barton recorder and set of orifice plates for each meter, 2”  &  1” Nu-Flo oil metering and 1” Nu-Flo water metering with digital readouts, Vessel protected by twin pilot operated PSV safety valves and including Ex lighting with power supply cable.

    1 x 50psi / 50 Bbl twin compartment vertical Surge tank in frame including lifting sling set. Inlets, outlets and bypass manifold with ball valves, sight glasses, hi-lo level alarms, steam coil and including Ex lighting with power supply cable.

    1 x 5000BPD / 100psi Transfer pump in frame including lifting sling set, centrifugal type pump with outlet check valve. Ex electricalmotor drive and On / Off switch box including power supply cable.

    1 x 1440psi / 15000 BOPD, 4 head Oil burner in frame including lifting sling set, isolation ball valves for oil and air on each head withcheck valves on oil and air inlets and including gas pilot ignition system on each head supplied with push button and power supply cable.

    1 x Set of ball valve diverter manifolding on base skids with lifting sling sets. Consists of 1 x 3” 1440psi 5 valve Oil manifold and 1 x3” 1440psi 2 valve Gas manifold

    1 x Set of pipework supplied on pipe racks with lifting slings sets. Consists of 3”602 5Kpsi pipework x 50ft / 3”206 2Kpsi pipework x 100ft / 4”206 2Kpsi pipework x 100ft and including elbows, tees and crossovers for each size and pressure rating.

    1 x 12ft Office converted container including lifting sling set. Fully insulated, air conditioned with desks, drawers, over head cupboards, bench seat / storage box, single external access door and window, fridge, fire extinguisher. Supplied with  50 meters supply cable , external isolator, transformer with input range of 220-690V, voltage stabilizer, distribution panel and output range of 110-220V to wall sockets and including UPS for DAQ acquisition system.

    1 x 10ft Workshop / Storage container with lifting sling set. Standard container double door access and supplied with steel workbench with cupboards and drawers, storage racks, bench vice, toolboard, whiteboard, and wall mounted cooling fan. Includes 50 meters power supply cable, external isolator, distribution panel and 220V internal sockets.








cost conscious well testing packages > Magnum Technology Center > Offshore well testing packages > oilfield supplies > onshore well testing packages > trailer mounted well testing packages > well testing > well testing packages

Name

Additional Equipment,1,Ancilliaries,1,Blast Resistant Modules,1,Buildings,3,Cost Conscious Package,1,Data Sheet,1,Gallery,7,Managed Pressure Drilling,6,Managed Pressure Drilling Gal,1,Modular Buildings,1,Off Shore Package,1,On Shore Package,1,Slider,4,Technical Buildings,1,Trailer Package,1,Underbalanced Drilling,3,Underbalanced Drilling Gal,1,Well Testing,7,Well Testing Gal,5,
ltr
item
Magnum Technology Center FZE: Well Test Cost-Conscious Package – Availability Update
Well Test Cost-Conscious Package – Availability Update
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhlnSQ56vEuM5wOMPhJbJNbpHUtXbIcdMOP3tz2d5Jm2XU7YhFzOFDvWi1eQ6OIm4knvR1X9blsEjt6LhB_IlvXIcdudA5XSos3aoFX0bLitrOTwPbxrwZzvEmJRl4jv6GEq8hP1jTLb9vp/s320/DSC_4457F1.jpg
https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhlnSQ56vEuM5wOMPhJbJNbpHUtXbIcdMOP3tz2d5Jm2XU7YhFzOFDvWi1eQ6OIm4knvR1X9blsEjt6LhB_IlvXIcdudA5XSos3aoFX0bLitrOTwPbxrwZzvEmJRl4jv6GEq8hP1jTLb9vp/s72-c/DSC_4457F1.jpg
Magnum Technology Center FZE
https://blog.mtc-intl.com/2020/05/well-test-cost-conscious-package.html
https://blog.mtc-intl.com/
https://blog.mtc-intl.com/
https://blog.mtc-intl.com/2020/05/well-test-cost-conscious-package.html
true
5635744125373387515
UTF-8
Loaded All Posts Not found any posts VIEW ALL Readmore Reply Cancel reply Delete By Home PAGES POSTS View All RECOMMENDED FOR YOU LABEL ARCHIVE SEARCH ALL POSTS Not found any post match with your request Back Home Sunday Monday Tuesday Wednesday Thursday Friday Saturday Sun Mon Tue Wed Thu Fri Sat January February March April May June July August September October November December Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec just now 1 minute ago $$1$$ minutes ago 1 hour ago $$1$$ hours ago Yesterday $$1$$ days ago $$1$$ weeks ago more than 5 weeks ago Followers Follow THIS CONTENT IS PREMIUM Please share to unlock Copy All Code Select All Code All codes were copied to your clipboard Can not copy the codes / texts, please press [CTRL]+[C] (or CMD+C with Mac) to copy